Temperature controllers for molds and hot runners, with zone count, sensor type and cooling capacity matched to your cell.

Sesuai dengan mesin yang benar-benar anda jalankan

Berikan model mesin, ton atau ruang sedia ada. Kami sahkan unit tepat, kawalan dan pilihan sebelum menawarkan harga.

Ditawarkan mengikut spesifikasi yang disahkan

Ulasan kejuruteraan Isnin hingga Sabtu. Berikan model mesin dan pengeluaran yang diperlukan — jawapan membawa harga, skop dan penghantaran.

Sesuai dengan peralatan sedia ada anda

Pengering, penyejuk, penghancur dan seluruh sel acuan, dikonfigurasi mengikut susun atur kilang dan peralatan sedia ada anda.

Email kejuruteraan

Tidak pasti saiz mana sesuai? Hantar model mesin atau foto unit sedia ada dan kami padankan.

Butiran

Spesifikasi & aplikasi

The temperature controller is the brain of the heating system. Its zone count, control algorithm and alarm logic decide whether temperature holds steady — and how fast a fault can be found when it does not.

Selection dimensions

DimensionWhat to consider
Zone countMatch the number of heating zones, with 10–20% reserve
Control algorithmOn/off, PID, adaptive PID; precision parts need PID or better
Input typeJ/K thermocouple or PT100 — must match what is actually wired
OutputRelay or SCR; frequent switching calls for SCR
AlarmsSeparate alarms for broken sensor, over-temperature, open heater
CommunicationWhether it must connect to the machine or plant system

Common configuration mistakes

  • Too few zones — one controller driving several zones that fight each other.
  • Wrong thermocouple type setting — display and reality differ by tens of degrees.
  • No broken-sensor alarm — a failed thermocouple makes the controller output full power and burn the heaters.
  • No soft start — full power into a cold system shortens element life.
  • Default PID parameters never tuned — temperature oscillates for the life of the job.

Commissioning points

  • Step the first heat-up gradually to drive off moisture and volatiles.
  • Tune PID at the normal operating temperature, not at the extremes.
  • Verify each zone against its physical position and mark it.
  • Record normal current values per zone as the baseline for later diagnosis.