Dongguan, Guangdong, Tiongkok
Minta penawaran
Pengendali suhu (TCU) — zona dan sensor
Peralatan pendukung

Pengendali suhu (TCU) — zona dan sensor

Temperature controllers for molds and hot runners, with zone count, sensor type and cooling capacity matched to your cell.

Sesuai mesin yang benar-benar Anda jalankan

Sertakan model mesin, tonase, atau ruang yang tersedia. Kami konfirmasi unit persisnya, kontrol, dan opsi sebelum menawar.

Ditawarkan sesuai spesifikasi yang dikonfirmasi

Review teknik Senin sampai Sabtu. Sertakan model mesin dan output yang dibutuhkan — jawaban berisi harga, cakupan, dan pengiriman.

Sesuai peralatan yang sudah Anda miliki

Pengering, chiller, granulator, dan seluruh sel molding, dikonfigurasi sesuai tata letak pabrik dan peralatan yang sudah Anda miliki.

Email ke tim teknik

Belum yakin ukuran mana yang pas? Kirim model mesin atau foto unit yang ada, kami cocokkan.

Detail

Spesifikasi & aplikasi

The temperature controller is the brain of the heating system. Its zone count, control algorithm and alarm logic decide whether temperature holds steady — and how fast a fault can be found when it does not.

Selection dimensions

DimensionWhat to consider
Zone countMatch the number of heating zones, with 10–20% reserve
Control algorithmOn/off, PID, adaptive PID; precision parts need PID or better
Input typeJ/K thermocouple or PT100 — must match what is actually wired
OutputRelay or SCR; frequent switching calls for SCR
AlarmsSeparate alarms for broken sensor, over-temperature, open heater
CommunicationWhether it must connect to the machine or plant system

Common configuration mistakes

  • Too few zones — one controller driving several zones that fight each other.
  • Wrong thermocouple type setting — display and reality differ by tens of degrees.
  • No broken-sensor alarm — a failed thermocouple makes the controller output full power and burn the heaters.
  • No soft start — full power into a cold system shortens element life.
  • Default PID parameters never tuned — temperature oscillates for the life of the job.

Commissioning points

  • Step the first heat-up gradually to drive off moisture and volatiles.
  • Tune PID at the normal operating temperature, not at the extremes.
  • Verify each zone against its physical position and mark it.
  • Record normal current values per zone as the baseline for later diagnosis.