Dongguan, Guangdong, China
Minta sebut harga
Jalur mika silinder — susunan zon
Jalur mika silinder

Jalur mika silinder — susunan zon

Mica barrel heater bands for injection and extrusion machines: 60-400 mm ID, 40-200 mm width, 500-3000 W per zone, with terminal boxes and thermocouple options.

Sesuai dengan mesin yang benar-benar anda jalankan

Berikan model mesin, ton atau ruang sedia ada. Kami sahkan unit tepat, kawalan dan pilihan sebelum menawarkan harga.

Ditawarkan mengikut spesifikasi yang disahkan

Ulasan kejuruteraan Isnin hingga Sabtu. Berikan model mesin dan pengeluaran yang diperlukan — jawapan membawa harga, skop dan penghantaran.

Sesuai dengan peralatan sedia ada anda

Pengering, penyejuk, penghancur dan seluruh sel acuan, dikonfigurasi mengikut susun atur kilang dan peralatan sedia ada anda.

Email kejuruteraan

Tidak pasti saiz mana sesuai? Hantar model mesin atau foto unit sedia ada dan kami padankan.

Butiran

Spesifikasi & aplikasi

Barrel heater bands wrap the feed, compression and metering zones of an injection or extrusion barrel. Compared with nozzle bands they are wider, higher powered, and usually supplied with a protective terminal box because they operate in the busiest part of the machine.

Typical zone configuration

ZoneWidthPowerNotes
Feed zone60 - 120 mm800 - 2000 WOften water cooled underneath
Compression zone80 - 160 mm1200 - 3000 WHighest heat demand
Metering zone60 - 120 mm800 - 2000 WPaired with thermocouple
Nozzle25 - 60 mm150 - 600 WSee nozzle band heaters

Build options

  • Inside diameter 60 - 400 mm, made to the barrel OD
  • 304 stainless sheath, optional aluminized steel for faster warm-up
  • Terminal box with ceramic block, IP20 or splash-resistant
  • Built-in type J or K thermocouple, or a separate bayonet fitting
  • Two-piece hinged construction for retrofits where the barrel cannot be unbolted
  • Earth stud and high-temperature lead wire as standard

Why bands fail early

Almost every premature failure we see has one of three causes. Resin or purging compound has run down inside the band and carbonized, shorting the element. The band was clamped over a corroded or scaled barrel, so contact is poor and the element overheats locally. Or the lead wire was routed against a hot surface and the insulation hardened and cracked. All three are installation issues, not manufacturing defects, and all three are avoidable.

Pair these bands with barrel blankets to cut radiant loss, and check zone wiring against the hot runner control systems section if you run a manifold.