中国広東省東莞市
見積もり依頼
シリンダー・ホットランナー用熱電対
ヒーター

シリンダー・ホットランナー用熱電対

Thermocouples for barrel zones, nozzles and hot runners — J and K types, with probe length and connector matched to your controller.

実際にお使いの設備に合わせて

機種・型締力・設置スペースをお知らせください。お見積もりの前に、機種・制御方式・オプションを確定します。

確認済み仕様に基づく見積もり

エンジニアリングレビューは月〜土。機種と必要な生産能力をお知らせください。回答には価格・供給範囲・納期を含めます。

現行設備に合わせて

乾燥機・チラー・粉砕機など成形セル全体を、工場レイアウトと既存設備に合わせて構成します。

どのサイズが合うかお悩みですか?機種または現行設備の写真をお送りください。照合します。

詳細

仕様と用途

The thermocouple is the temperature-control system's eye. If it reads wrong, the controller corrects against the wrong value — and no heater, however good, can compensate. Many "burned heater band" problems actually start at the thermocouple.

Types

TypeMaterialsRangeNotes
J typeIron–constantanLow to medium temperatureCommon, inexpensive
K typeNiCr–NiSiMedium to high temperatureGood linearity, most widely used
PT100Platinum RTDLow to medium temperatureHigh accuracy, stable

Installation points

  • The sensing tip must sit where the temperature is to be measured: against the barrel wall for barrel zones, into the melt channel for melt readings.
  • Insert deep enough — a shallow probe reads ambient temperature, not the process.
  • Fasten it firmly; a loose thermocouple gives jumping readings.
  • Route lead wires away from power cables to reduce interference.
  • Compensation lead wire must match the thermocouple type; a mismatch shifts readings systematically.

Common mistakes

  • Wrong instrument type setting: a J-type wired as K can display a reading tens of degrees off.
  • Thermocouple and heater band in different zones — the controller then stabilizes a temperature that is not the one you set.
  • Testing with a multimeter's voltage range: check the millivolt signal or resistance, not supply voltage.
  • Several zones sharing one thermocouple — zone control then exists in name only.

When to replace

Jumpy readings, displayed values clearly out of line with an independent measurement, and heater power rising abnormally (the controller believing the zone is still cold) all point first at the thermocouple. Check it before suspecting the heater element.

関連製品

このシリーズの他のコンポーネント

カテゴリを見る

この部品をお使いの成形機に合わせる必要がありますか?

機種と樹脂をお知らせください。見積もりの前に幾何形状・材質・表面処理を確認します。

シリンダー・ホットランナー用熱電対 確認済み仕様に基づく見積もり