Dongguan, Guangdong, Tiongkok
Minta penawaran
Termokopel untuk silinder dan hot runner
Pemanas

Termokopel untuk silinder dan hot runner

Thermocouples for barrel zones, nozzles and hot runners — J and K types, with probe length and connector matched to your controller.

Sesuai mesin yang benar-benar Anda jalankan

Sertakan model mesin, tonase, atau ruang yang tersedia. Kami konfirmasi unit persisnya, kontrol, dan opsi sebelum menawar.

Ditawarkan sesuai spesifikasi yang dikonfirmasi

Review teknik Senin sampai Sabtu. Sertakan model mesin dan output yang dibutuhkan — jawaban berisi harga, cakupan, dan pengiriman.

Sesuai peralatan yang sudah Anda miliki

Pengering, chiller, granulator, dan seluruh sel molding, dikonfigurasi sesuai tata letak pabrik dan peralatan yang sudah Anda miliki.

Email ke tim teknik

Belum yakin ukuran mana yang pas? Kirim model mesin atau foto unit yang ada, kami cocokkan.

Detail

Spesifikasi & aplikasi

The thermocouple is the temperature-control system's eye. If it reads wrong, the controller corrects against the wrong value — and no heater, however good, can compensate. Many "burned heater band" problems actually start at the thermocouple.

Types

TypeMaterialsRangeNotes
J typeIron–constantanLow to medium temperatureCommon, inexpensive
K typeNiCr–NiSiMedium to high temperatureGood linearity, most widely used
PT100Platinum RTDLow to medium temperatureHigh accuracy, stable

Installation points

  • The sensing tip must sit where the temperature is to be measured: against the barrel wall for barrel zones, into the melt channel for melt readings.
  • Insert deep enough — a shallow probe reads ambient temperature, not the process.
  • Fasten it firmly; a loose thermocouple gives jumping readings.
  • Route lead wires away from power cables to reduce interference.
  • Compensation lead wire must match the thermocouple type; a mismatch shifts readings systematically.

Common mistakes

  • Wrong instrument type setting: a J-type wired as K can display a reading tens of degrees off.
  • Thermocouple and heater band in different zones — the controller then stabilizes a temperature that is not the one you set.
  • Testing with a multimeter's voltage range: check the millivolt signal or resistance, not supply voltage.
  • Several zones sharing one thermocouple — zone control then exists in name only.

When to replace

Jumpy readings, displayed values clearly out of line with an independent measurement, and heater power rising abnormally (the controller believing the zone is still cold) all point first at the thermocouple. Check it before suspecting the heater element.

Terkait

Komponen lain dalam rangkaian ini

Lihat kategori

Perlu komponen ini disesuaikan dengan mesin Anda?

Sertakan model mesin dan resin — kami konfirmasi geometri, material, dan perlakuan sebelum menawar.

Termokopel untuk silinder dan hot runner Ditawarkan sesuai spesifikasi yang dikonfirmasi