Hot runner temperature controllers from 1 to 48 zones with PID autotuning, soft start, zone alarms and thermocouple break detection.

Sesuai mesin yang benar-benar Anda jalankan

Sertakan model mesin, tonase, atau ruang yang tersedia. Kami konfirmasi unit persisnya, kontrol, dan opsi sebelum menawar.

Ditawarkan sesuai spesifikasi yang dikonfirmasi

Review teknik Senin sampai Sabtu. Sertakan model mesin dan output yang dibutuhkan — jawaban berisi harga, cakupan, dan pengiriman.

Sesuai peralatan yang sudah Anda miliki

Pengering, chiller, granulator, dan seluruh sel molding, dikonfigurasi sesuai tata letak pabrik dan peralatan yang sudah Anda miliki.

Email ke tim teknik

Belum yakin ukuran mana yang pas? Kirim model mesin atau foto unit yang ada, kami cocokkan.

Detail

Spesifikasi & aplikasi

A hot runner lives or dies on temperature control. A zone that overshoots on start-up carbonizes the resin; a zone that reads the wrong thermocouple runs cold and produces short shots that look like a pressure problem.

System options

ParameterRange
Zones1, 2, 4, 8, 12, 24, 48 zone cabinets
InputType J or K thermocouple, grounded or ungrounded
OutputTriac or relay, 15 A per zone typical
ControlPID with autotune, manual override per zone
Accuracy±1 °C steady state
FeaturesSoft start, boost, standby, zone alarm, TC break detection
CommsOptional RS485 / Ethernet to machine HMI

What to look for

  • Soft start limits output until moisture is driven out of the heater — the single biggest life extender for hot runner heaters
  • Thermocouple break detection stops a zone running open loop at full power
  • Per zone current display lets a setter spot a failing heater before it takes a drop down
  • Standby mode drops zones to a holding temperature during breaks instead of cycling fully off
  • Labelled connectors matched to your existing hot runner cartridge heaters

We size cabinets to the manifold, not to a catalogue page: tell us the number of drops, the heater wattage per zone, the thermocouple type and the connector you already use.