Patronenheizungen für Heißkanäle und Düsen
Hot runner and nozzle cartridge heaters in 6.5 mm and 8 mm diameters with tip-sensitive thermocouples, swaged construction and tight diameter tolerance.
Details ansehen
Hot runner and nozzle cartridge heaters in 6.5 mm and 8 mm diameters with tip-sensitive thermocouples, swaged construction and tight diameter tolerance.
Nennen Sie uns Maschinenmodell, Schließkraft oder Bauraum. Wir bestätigen das genaue Gerät, die Steuerung und die Optionen vor der Preisgabe.
Engineering-Review Montag bis Samstag. Nennen Sie Maschinenmodell und benötigte Leistung — die Antwort enthält Preis, Lieferumfang und Lieferzeit.
Trockner, Kühler, Granulatoren und der Rest der Zelle, konfiguriert für Ihre Halle und Ihre bestehende Ausrüstung.
Unsicher, welche Größe passt? Schicken Sie das Maschinenmodell oder ein Foto des vorhandenen Geräts — wir gleichen es ab.
Hot runner heaters are a category of their own. They have to fit a bore that is often under 10 mm, respond fast enough to hold melt temperature shot to shot, and survive being pulled and refitted every time a tip is changed.
| Parameter | Range |
|---|---|
| Diameter | 6.0, 6.5, 8.0, 10 mm standard |
| Length | 40 - 250 mm |
| Power | 100 - 500 W |
| Watt density | 15 - 25 W/cm² |
| Sheath | 316L stainless, swaged |
| Thermocouple | Type J or K, tip sensitive, grounded or ungrounded |
| Lead | 300 - 1000 mm, stainless braid or fiberglass sleeve |
| Connector | Standard 2-pin or 4-pin plug to suit common controllers |
Diameter tolerance is the first. A hot runner bore is reamed to H7 and the heater is expected to slide in with light finger pressure but still make full contact; a nominal 6.5 mm element that measures 6.42 mm will run hot at the tip and cold at the base. We hold -0.02 / -0.05 mm on request and mark the actual size on the body.
Second is thermocouple placement. A tip-sensitive sensor reads the melt where it matters and reacts within a couple of seconds; a sensor buried at the lead end reads the manifold instead and lets the tip run cold. Third is the connector: match it to the controller you already own rather than changing plugs across the shop.
For the control side, see hot runner control systems. For general mold heating, the standard cartridge range covers most cavities.
Hot runner and nozzle cartridge heaters in 6.5 mm and 8 mm diameters with tip-sensitive thermocouples, swaged construction and tight diameter tolerance.
Details ansehenNennen Sie Maschinenmodell und Kunststoff — wir bestätigen Geometrie, Werkstoff und Wärmebehandlung, bevor wir das Angebot erstellen.
Zeichnung vorhanden? Antworten Sie auf unsere Bestätigungs-E-Mail mit der Datei — PDF, STEP, DXF oder ein Foto des Teils funktionieren alle.
Unser Engineering-Team antwortet während der Arbeitszeiten, Montag bis Samstag. Für dringende Aufträge rufen Sie an: +8613751260808.